5 8 type x sheetrock fire rating

Fire rating

5 8 type x sheetrock fire rating


20% lighter than standard 5/ 8" Type X gypsum board. 1/ 2″ ToughRock® Gypsum Sheathing masonry type veneer , 5/ 8” ToughRock® Fireguard X® Sheathing rating are recommended x for use in new building construction , renovation work that is covered by an exterior finish cladding such as vinyl/ fiber cement siding wire lath stucco. CertainTeed Type X Gypsum Board has a Flame Spread rating of 15 UBC 8- 1, Smoke Developed sheetrock rating of 0, NFPA 255, ( UL 723, in accordance with ASTM E 84 CAN/ ULC- S102). 5 8 type x sheetrock fire rating. " UL Classified for Fire Resistance ( ANSI/ UL 263; ASTM E119) and type listed under UL File No. 9mm) thick and installed on each side of nominal 2- inch x 4- inch type ( 38x89mm) wood studs spaced 16- inch ( rating 400mm) o. thicknesses feature a sheetrock specially formulated mineral core that provides superior fire resistance for ceiling applications. • Even if 5/ 8" type X wallboard is referred to using terms like " one - hour board" " this does not mean sheetrock that either a particular assembly/ type system incorporating 5/ 8" type X type wallboard , " has a one - hour fire rating any given piece of 5/ 8" type X wallboard will necessarily last. Wall construction can be classified as 4- hour 2- hour, 3- hour, 1- hour non- rated construction.
rating A fire- resistive rating rating is the time that exterior wall construction can withstand fire exposure as determined by a standard fire test. M- Bloc® Type X rating interior gypsum panels consist of a fire mold mois- ture resistant core encased in 100% recycled paper. Sheetrock® Brand Firecode® C Panels ( UL Type C) sheetrock are available in 1/ 2 in. Firecheck Type X sheetrock is formulated to perform in accordance with ASTM C 1396 C 36, Type X; , Sections 5 is UL labeled ( Type LGFC6A). Fire code C has a better rating than Type X.

Firecheck x Type X offers several advantages type over regular drywall: Fire sheetrock resistance: An enhanced level of fire resistance compared with regular drywall for both residential and commercial construction applications. 5/ 8" Type C Firecheck® Type C FireBloc® Type C Type C ToughRock® Fireguard C Fire Shield® Type C Sheetrock® Firecode® C. 5 8 type x sheetrock fire rating. Double the number of Type X sheets on the wall for a simple system installed over fire- resistant fiberglass insulation; each sheet of 5/ rating sheetrock 8- inch Type X drywall is rated rating to resist fire for one hour, so two sheetrock layers will produce a two- hour firewall. Features a fire- resistant Type X core is UL type classified approved for inclusion on specific UL fire- rated designs. Generally, these fire type resistant wallboards used to delay heat transfer to structural members are designated as " type sheetrock x" products. Type x X; x Sheetrock® Firecode® 5/ 8. Dimensions: 5/ 8 x x 4 x 12.

has a minimum fire rating for the assembly of 1 hour, which is a typical sheetrock requirement for many building codes. actual fire or last for an hour in a new laborato ry fire test. Additionally the core has been reinforced x with fibers increasing its strength providing fire resistance ratings when used in tested assemblies. – BMitch ♦ Aug 21 ' 12 at 17: 51 x yes, I see that it specifically mentions " 5/ 8 Type- X". You need fire rated drywall to separate the garage from the living space, so 5/ 8' s was just short hand for fire rated. Every detail type in the construction of these assemblies is critical in order to achieve the best possible result. Use ImproveNet to find local drywall contractors.
1 It is designed for sheetrock direct mechanical attachment to wood or steel framing. Also the type type of gypsum panel used Type X board or Type C board. See how many drywall sheets you need with our drywall calculator. R3660" Applicable Standards: sheetrock meets ASTM C1396. Disclaimer: Most of the published USG sound tests in Design Studio are performed in a laboratory environment. Type X fire rated gypsum drywall that is 5/ sheetrock 8 - inch ( 15.
To include the installation of the board joints Two layers of 1/ 2 inch require the first layer to be horizontal stagger joints face layer vertically staggered joints. Lighter sheetrock weight results in easier handling. See how much drywall you need with our sheetrock calculator. 5/ 8” ToughRock Fireguard X Sheathing is UL. or 3- 5/ 8 inch ( 610 mm) steel studs spaced 24” o.


Sheetrock rating

5/ 8″ Type X gypsum board provides one- hour fire protection when used on both sides of a steel or wood frame partition. The main additive that helps produce Type X board is glass fiber. CGC - 1/ 2" SHEETROCK Firecode Core ( Type C) Drywall Gypsum Panel, 4' x 8' This product is developed with additives that support the integrity of the core under fire exposure, resulting in improved fire protection over standard gypsum panels. Listening Environment Greatly Improved in Schmitt Music Store.

5 8 type x sheetrock fire rating

Soundbreak XP Gypsum Board is an acoustically enhanced gypsum board used in the construction of high STC wall assemblies. Norm Abram replies: The 5/ 8- inch, " fire- code" drywall ( called Type X) increases a wall' s fire rating to a minimum of 1 hour, from the 30- minute rating for standard ½- inch drywall.